Pulnix TMC-6 Manuel d'instructions Page 38

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 45
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 37
Page 30
Operation
TM-1402 Series Progressive Scan Shutter Cameras
Model: TM-1402 Operation Mode: 98.7 Frames/Second
Master Clock: 100 MHz, M= 10 nsec
Pixel Clock: 50 MHz, P = 20 nsec
3. External Reset Timing (Partial Scan 250 Lines)
4. Async Shutter Reset Timing (Partial Scan 250 Lines)
External VD
Internal VD
FDV
Digital Data
Analog Video
VINIT Trigger
Internal VD
FDV
Digital Data
A
nalog Video
Horizontal Frequency: 31.09 KHz
1H = 32.16 usec
A [315 H], (10.13 ms)
B [1 H], (32.16 us)
C [9 H], (289.44 µs)
D [306 H], (9.84 ms)
E [ 315 H], (10.13 ms)
K [3 H], (96.48 us)
F [65 H], (2.09 ms)
H [65 H], (2.09 ms)
J [62 H], (1.99 ms)
L [3 H], (96.48 µs)
G [250 H], (8.04 ms)
I [250 H], (8.04 ms)
M [250 H], (8.04 ms)
P [306 H], (9.84 ms)
R [ 315 H], (10.13 ms)
V [250 H], (8.04 ms)
Y [250 H], (8.04 ms)
N [Variable H], (µs)
W [62 H], (1.99 ms)
U [65 H], (2.09 ms)
Z [3 H], (96.48 µs)
Q [3 H], ( 96.48 µs)
O [9 H], (289.44 µs)
S [65 H], (2.09 ms)
X [3 H], (96.48 µs)
T [250 H], (8.04 ms)
Note: For color camera, FDV=252H (async only)