Operation
TM-1405GE Hardware
8.9 External HD Locking and External VD Reset
Table 9. External HD Locking and External VD Reset (Horizontal Timing)
Table 10. External HD Locking and External VD Reset (Vertical Timing)
8.10 Asynchronous Reset
Table 11. Asynchronous Reset
Horizontal Timing
Number of
pixels
30fps
(μs)
eA <1 <0.02
eB 160 3.20
eC 1448 28.96
eD 15 0.30
Vertical Timing
Full Scan Area User Scan Area (SP:x, TL:y)
Number of
lines
30fps
(μs)
Number of lines
30fps
(μs)
eE <1 <32.16 <1 <32.16
eF 9 289.44 9 289.44
eG 1404 45152.64 (nfp+2)+nrp+y ((nfp+2)+nrp+y)*32.16
eH 0 0 0 0
(L: lines)
(P: pixels)
30 fps
(μs)
aA <1L <32.16
aB 9L + 960P 308.64
aC 160P 3.20
aD 9L 289.44