2.5 Digital Video timing
The falling edge of either LDV or FDV with respect to the next rising edge of clock is significant when area cameras
are selected.
The rising edge of LDV with respect to the next rising edge of clock is significant when linescan cameras are
selected.
The below timings are measured at the outputs of the RS-644 linereceivers.
tclk tdsu tdh tvsu
25 ns min 10ns min 10ns min 10 ns min
CLOCK
DATA
FDV
LDV
10 ns max.
tclk
tdh
tvsu
tdsu