Page 90
VIS CAM 300/400 Installation Manual
Appendix C: Two Cameras, One Flash Configuration
7 Appendix C: Two Cameras, One Flash Configuration
Figure 7.1 shows how to connect one flash to two VIS CAM 300 cameras. The flash output from
camera 0, the master camera, is connected to the laser trigger input on camera 1, the slave camera. The
Flash unit is connected to the slave camera.
The flash output must always be enabled on the master camera. The flash output on the slave camera is
setup as normal (controlled by the values from the light sensor).
FIGURE 85. Two camera, one flash, configuration.