Pulnix TS-9720EN Series Manuel d'installation Page 103

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 116
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 102
Page 91
VIS CAM 300/400 Installation Manual
Appendix C: Two Cameras, One Flash Configuration
Three wires are connected from the flash connector on the IO Board of the Master camera to the laser
(LVD) connector on the IO Board of the Slave camera:
TABLE 34. Master to slave connections.
Junction Panel trigger polarity switch in position “positive going edge”
Master camera flash must be set to “auto” in Properties section of ENSetup software
Slave camera flash must be set to “light sensor control” in properties section of ENSetup software
Master Flash Connector
(X5)
Slave Laser Connector
(X7)
Pin 2 Pin 2
Pin 3 Pin 3
Pin 5 Pin 1